beautypg.com

NORAC 4465BC+JD User Manual

Page 9

background image

6

Figure 5: An Acceptable Mounting

Avoid mounting sensors in locations

where they may read from parts of
the boom as shown in Figure 6.

Figure 6: Poor Mounting

(Sensor reading off boom)

General mounting rules for UC4+
ultrasonic wing sensors:

a) In its lowest position, the sensor mouth

must be 9 inches or more from the ground.

b) The bottom of the sensor must be at least 9

inches in front of the spray nozzles.

c) The bottom of the sensor must be at least 9

inches above the spray nozzles.

d) Ensure that there are no obstructions within

a 12-inch diameter circle projected directly
below the center of the sensor.

e) The sensor should be approximately vertical

at normal operating heights.

Figure 7: Sensor Mounting Guidelines

A

B

B

D

C

Ultrasonic
Acoustic Cone