4 installation procedure, 1 sensor installation – NORAC 4465BC+JD User Manual
Page 8
5
4
INSTALLATION PROCEDURE
4.1 S
ENSOR
I
NSTALLATION
1. Assemble the Breakaway Sensor Mounting
Brackets (B11) as show in Figure 3 and
Figure 4.
Figure 3: Breakaway Sensor Bracket
Exploded View
Figure 4: Breakaway Sensor Mounting
Bracket Assembly
To assemble the breakaway sensor bracket:
a) Assemble the bolt and nut into the
collar.
b) Grease the bottom edge of the collar
and the angled tube of the base.
c) Place the collar onto the angled tube of
the mounting base.
d) Install the spring between the collar and
the upper ring of the base.
e) Insert tube through assembly and tighten
the collar
2. Mount the sensor brackets onto the boom
half way between the tip and center of the
sprayer (Figure 8).
3. The sensor mounting brackets can be
installed with the mounting base behind or in
front of the tube.
If possible, mount the sensor
brackets while the booms are in their
folded position to ensure that they
will not interfere with anything when
the boom is folded for transport.
4. Mount the NORAC UC4+ ultrasonic sensor
(E02) into the sensor brackets. The sensors
should be oriented forward (ahead) of the
boom (see Figure 5 and Figure 7).
When installing the UC4+ sensors
(E02), start with the smallest serial
number on the left hand side
proceeding to the largest serial
number on the right hand side
(Figure 8).
5. Sensor cables should run through the
mounting bracket tube and then behind the
member the bracket is mounted onto.
Cable-tie the connector in place. The cable
must not be allowed to hang below the
boom (Figure 5).