beautypg.com

NORAC UC4+BC+MC2 User Manual

Page 25

background image

22

Figure 25: Cable Configurations: C10, C11 and C14

2. Connect the UC4+ power cable (C10)

to the UC4+ control panel in the
sprayer cab. Ensure both plugs (P16
and P4) are connected to the panel
(Figure 25).

Ensure the UC4+ Panel’s power

is OFF for the remaining
installation (Bottom of switch
pressed IN).

3. Connect the 3-pin AMP plug (P3) of

C10 to the 3-pin AMP receptacle (R3)
of C14.

4. Connect the other end of C14 to a

12V, 15 amp source.

5. Route the receptacle end (R16) of C10

out of the cab.

6. Connect the 16-pin AMP plug (P16) of

the valve extension cable (C11) to R16
of C10 (Figure 25).

Figure 26: Cable Configurations: C03, C11 and C12