4.6.2 Valve Mounting
1. Mount the NORAC valve (V01) on the

sprayer using the valve mounting

bracket.

2. Screw short side of the threaded rods

into the bottom of the valve block at
least 3/8". The valve mounting holes are
drilled and tapped 3/8 NC-1" deep.

3. Tighten the Hex nuts to hold the rods.

4. Put the mounting bracket on the other

side of the tube and tighten with the
spring washers and the Hex nuts.

5. Cut excess off of the studs, if necessary.

If using bolts, the bolts should

thread into the valve block at
least 3/8". The valve mounting
holes are drilled and tapped 3/8
NC-1" deep. The rule of thumb
for bolt length is 1-1/2" longer
than the tube size.

You must ensure no hydraulic

components will interfere with
any sprayer parts or be pulled

tight at any time.

Figure 23: Valve Mounting Location