4.6 H

YDRAULIC

I

NSTALLATION

WARNING!

The hydraulic system creates very
high pressure. Before disconnecting
any hydraulic lines ensure all pressure
has been bled from the system.

When changing the boom hydraulic
hoses leave the booms in
TRANSPORT POSITION.

IMPORTANT:

Component failure due to oil
contamination is not covered under
the UC4+ Spray Height Control
system warranty. It is recommended
that a qualified technician does the
hydraulic installation.


4.6.1 Valve Assembly
1. On a clean surface remove all plastic

plugs from the NORAC hydraulic Valve
(V01) (Figure 19).

Figure 19: NORAC Valve Block

2. Install the 6MB-6MOR fittings (F03)

into the “P” and “T” ports on the
NORAC valve block and tighten to 18
ft-lbs.

3. Install the orifices (F10) into the "B"

ports with the notch facing outward
as shown in Figure 20.

4. Install the 6MB-8MOR fittings (F11)

into the “B” ports and tighten to 18 ft-
lbs.

4.

Install the 6MBP plugs (F05) into the
“A” ports and tighten to 18 ft-lbs.

Ensure that the orifices are oriented
properly for the “B” ports or the
system will not function properly.

Figure 20: Valve Block Assembly