4.5.2 Intermediate Frame Roll Sensor Mounting
The intermediate frame roll
sensor has the temperature
probe on it.
1. It is often best to cable tie the
intermediate frame roll sensor in place.
When mounting the intermediate frame
roll sensor follow the guidelines and
refer to Figure 15 and Figure 17.
The intermediate frame roll
sensor must be mounted on a
portion of the sprayer that does
not pivot and is as close to the
boom frame roll sensor as
possible (Figure 13).
a) Make sure you are using the roll
sensor with the temperature probe
(E03).
b) Ensure the roll sensor is level with
respect to the chassis.
c) The AMP (circular) connector
MUST exit towards the right
hand wing (when looking from the
rear of the sprayer).
d) Make sure the temperature probe is
able to reach the side of the valve
block.
Figure 15: Intermediate Roll Sensor
Mounting
2. Fasten the temperature probe to the
UC4+ valve block, using the supplied
3/8”x1/2” bolt as shown in Figure 16.
3. Cable-tie the temperature probe cable
and AMP (circular) connector securely
to a frame member.
Check that the roll sensors and
cables will not interfere with, or
come into contact with any parts
of the sprayer.
Figure 16: Temperature Probe
Attached to the UC4+ Valve Block