beautypg.com

3 hydraulic installation – NORAC UC4+CS4-4B User Manual

Page 8

background image

6

3

HYDRAULIC INSTALLATION

WARNING!

The hydraulic system creates very
high pressure. Before disconnecting
any hydraulic lines ensure all pressure
has been bled from the system.

IMPORTANT:

Component failure due to oil
contamination is not covered under
the UC4+ Spray Height Control
system warranty. It is recommended
that a qualified technician does the
hydraulic installation.

Sprayers with a model year of

2007 and older require the main
lift valve to be changed. See
Section 4 for instructions on how
to do this.

1. Use Figure 1 as a reference for

installing the hydraulics.

2. Install the 6MB 6MOR fitting (F04) into

the A and B ports of the expansion
block (Figure 2).

Figure 2: Expansion Block Assembly

3. Remove the four 4MBP plugs from the 2

station valve block.

4. Coat the four o-rings in hydraulic oil

and install them into the expansion
block. Ensure the o-rings are seated
properly.

5. Attach the expansion block to the 2

station block using the included spring
washers and bolts.

6. Tighten the bolts to 31 ft-lbs.

Figure 3: Expansion Valve Final Assembly