beautypg.com

2 roll sensor mounting: tr4, tr4r – NORAC UC4.5-BC-EV1 User Manual

Page 18

background image



15

6.2 Roll Sensor Mounting: TR4, TR4R

1. Mount the roll sensors (E03 and E04) to the boom center section, as illustrated in Figure

15. Ensure the 6 pin connector is pointing towards the right hand wing (when looking from

the rear of the sprayer).

2. Item E03 (has temperature probe) is attached to the non-rotating part of the boom. Use

bolts or cable ties.

3. Item E04 is attached to the rotating part of the boom (to the EVRARD valve block

mounting bracket (EVRARD06) as pictured). If mounted to item EVRARD06 as shown, the
NORAC roll sensor mounting bracket is not required. Otherwise, mount in a similar
fashion, using the roll sensor mounting bracket.

4. Ensure that the rod-end jam nut is tight and that there is no free play in the threads of the

rod-end. Free play in this area will reduce roll sensor performance.

Figure 15: Boom Roll Sensor Mounting

E04

E03