9. Insert the 2-conductor wire into the power distribution box and connect to power and

ground. It is also possible to connect power and ground within the SHC box.

RAU CONNECTION

C18 WIRE

+12V (6 AMP rating)

BLACK (on 2 conductor wire)

GROUND

WHITE (on 2 conductor wire)

Figure 16: C18 Harness Connected within SHC Enclosure

IMPORTANT: Be sure the power connection is wired correctly. Damage to the

circuit board may result if the power connection is reversed.

10. Fasten the 3-way coupler to the boom with cable ties. Connect P6 on C11 to the 3-way

coupler.

11. Connect two cables (C05) to the 3-way coupler and route along the booms to the wing

sensors. Follow existing cables and hoses to be sure the cable will not be pinched or
stretched.

12. At the sensor brackets, attach a 2-way coupler with terminator (E20) to the sprayer boom.

The 2-way coupler with terminator is the white two way coupler. Plug the sensor and the
CANbus cable into the 2-way coupler.

IMPORTANT:

Provide enough slack in all cables to account for the movement of the main
section, parallel lift, and FOLDING boom movement.

C18

Harness