ENVIRONMENTAL
Temperature
-10F
to
+12OF
Humidity 90%
RH,
Non-condensing
Surge
2500
V,
Per
ANSI
C37-90A-1974, common and
differential mode
EMI/RFI
per
FCC
part
15C
ELECTRICAL
Power requirements
120 VAC, 50/60 Hz, 7 watts
Fault sensing current
Less then 10 mA per channel
Battery
Backup 4
hours
typical
Power outage detection time
1-99 seconds
PHYSICAL
Dimensions
11 5/8 x 9 7/16 x 4 inches
Weight
10
lbs.
Mounting method
Flange mount, 4 points
Enclosure
NEMA
12
std.,
others
optional
TELEPHONE SYSTEM
FCC registered for direct interconnect
FCC Registration Number:
D4J6M6-13598-AL-E
Dialing capacity
8 numbers, 16 digits each,
maximum
Dialing format
Loop disconnect, 10 pps
nominal; or tone,
100ms/100ms;
user
selectable
Answer delay
Programmable, 1 to 99 rings
Acknowledged intercall delay
Programmable, 1 to 99 hours
Unacknowledged intercall delay
One Minute
Surge and environmental protection
Per FCC part 68
OPERATIONAL
Fault detection method
Normally open or closed,
selectable
Fault integration time constant
One to 99 seconds
Station
identification
Name
or number, user selectable
user programmable messages
Message repetitions
One to 99, user programmable
Data retention
Nonvolatile EEPROM
Programming
Local keyboard entry