Make Noise Optomix User Manual
Page 5
Panel Controls (cont’d)
8.
Signal IN CH. 2: Direct coupled signal input capable of accepting audio or control signals. Normalized
to Signal OUT CH. 1 for series processing. Range of up to 10Vpp.
9.
Control Signal IN CH. 2: Direct coupled, highly sensitive CV input for the corresponding channel’s
vactrol gate. Normalized to +8V so that with nothing patched the associated attenuator
operates as a manual control for the parameter. Range 0V-8V.
10. DAMP CV IN CH. 2: Direct coupled, CV input for the corresponding channel’s DAMP-ing parameter.
Normalized to +8V so that with nothing patched the associated attenuator operates as a
manual control for the parameter. Range 0V-8V.
11. DAMP Attenuator CH. 2: unipolar attenuator for DAMP CV IN. With nothing patched to the DAMP CV
IN, operates as a manual control for the parameter.
12. Control Attenuator CH. 2: unipolar attenuator for Control Signal IN. With nothing patched to the
Control Signal IN, operates as a manual control for the parameter.
13. Signal OUT CH. 2: Direct coupled output of the signal applied to the input, as pro-cessed by the LPG.
10Vpp (depending upon gate settings and source material).
14. STRIKE IN CH. 2: Gate input for striking or plucking the vactrol. Expects 8V Gate.
15. AUXiliary IN: Direct coupled signal input to the SUM circuit to allow for the chaining of multiple Opto
mix and modDemix units to create larger mixes. Capable of accepting audio or control signals.
Range of up to 10Vpp.
16. SUM OUT: The sum or mix of all signals processed by the Optomix is output at this jack. 10Vpp
(depending upon settings and source material).
1
2
3
4
6
5
8
7
11
14
15 16
13
12
10
9