beautypg.com

Make Noise Optomix User Manual

Page 4

background image

Panel Controls

1. Signal IN CH. 1: Direct coupled signal input capable of accepting audio or control signals. Range of up

to 18Vpp.

2. DAMP CV IN CH. 1: Direct coupled, CV input for the corresponding channel’s DAMPing parameter.

Normalized to +8V so that with nothing patched the associated attenuator operates as a manual control for

the parameter. Range 0V-8V.

3. Control Signal IN CH. 1: Direct coupled, highly sensitive CV input for the corresponding channel’s

vactrol gate. Normalized to +8V so that with nothing patched the associated attenuator operates as a

manual control for the parameter. Range 0V-8V.

4. DAMP Attenuator CH. 1: unipolar attenuator for DAMP CV IN. With nothing patched to the DAMP CV IN,

operates as a manual control for the parameter.

5. Control Attenuator CH. 1: unipolar attenuator for Control Signal IN. With nothing patched to the Control

Signal IN, operates as a manual control for the parameter.

6. Signal OUT CH. 1: Direct coupled output of the si gnal applied to the input, as pro-cessed by the LPG.

10Vpp (depending upon settings and source material).

7. STRIKE IN CH. 1: Gate input striking or plucking the vactrol. Expects 8V Gate.

1

2

3

4

6

5

8

7

11

14

15 16

13

12

10

9