Pitch Shift

1C. Temphonic LEDs: indicate mechanics of the pitch-shifting machine.

2C. Pitch Panel Control: bipolar panel control. At 50% no pitch shift, greater than 50% shifts pitch UP and

less than 50% shifts pitch DOWN. Range is ALWAYS dependent upon DEPTH setting.

3C. Pitch Trim (see calibration procedure)

4C. DEPTH Panel Control: unipolar panel control that sets the index of the pitch shift, ranging from sub-mi

crotonal chorusing to 4 octaves harmonizing.

5C. PITCH 1 CV Attenuator: bipolar attenuator for PITCH 1 CV IN.

6C. DEPTH CV Attenuator: unipolar attenuator for DEPTH CV IN.

7C. DEPTH CV IN: unipolar control signal input. Range 0V to +5V.

8C. PITCH 1 CV IN: bipolar control signal input. Range +/- 4V.

9C. PITCH 2 CV IN: bi-polar control signal input. Range +/- 2V for total of 4 octave range. Set Pitch Panel

Control to full CCW for uni-polar control such as analog sequencer, or to 50% for bi-polar

control signal such as CV Keyboard.

1C

3C

2C

3A

4C

5C

6C

7C

8C

9C