Problem
Probable Cause
Corrective Action
System will not turn on and
On/Off indicator light does
not illuminate
Coach ignition not in
RUN position
Turn ignition to RUN position
Parking brake not set
Set parking brake
Controls have been
on for more than four
minutes and have
timed out
Turn ignition OFF and then back ON
Control panel turns on but
turns off when jack button
is pushed or displays "Low
Voltage"
Low voltage on battery
Start coach to charge battery
Control panel turns on,
coach will not auto level,
"Jacks Down" displayed,
jacks are retracted
Low fluid level
Change fluid level in reservoir. If fluid is
low, add fluid to 1/2" from top of reservoir
with jacks retracted. If JACKS DOWN light
remains on, call Lippert Service.
Jacks will not extend to
ground, pump is running
Little to no fluid in
reservoir
Add fluid as recommended; See page 15.
Leg valve is inoperative
Clean, repair or replace
Electronic signal is lost
between control and
leg valves
Trace wires for voltage drop or loss of signal.
Repair or replace necessary wires or replace
control pad.
Any one or two jacks will
not retract
Hose damaged or
unconnected
Replace with new hose or reconnect hose
Valve inoperative
Replace inoperative valve
Electronic signal is lost
between control and
solenoid
Attempt to retract jacks in MANUAL mode.
If successful, replace control pad. If not,
test for voltage drop between control pad
and leg valve. Repair bad wiring or replace
defective board or valve.
"Jacks Retracted" does not
display when all jacks are
retracted
Low fluid level
Add fluid as recommended; See page 15.
Retract pressure switch
inoperable
Check connection or replace
Alarm sounds and "Jacks
Down" light starts flashing
while traveling, jacks are
fully retracted
Low fluid level
Add fluid as recommended; See page 15.
Retract pressure switch
inoperable
Check connection or replace
Jack bleeds down after
being extended
Valve Manual Override
open
Close override. See Page 13, Fig. 8.
Control panel powers
up, screen displays "Low
Voltage"
Engine not running
Start coach engine
No power to control panel
Tripped circuit breaker
Reset
Ignition not ON
Turn ignition ON
Auto level function does
not finish
Error code "Unable to
Finish Leveling"
Move coach to a more level site