Ground Control 3.0 Troubleshooting Guide
GROUND CONTROL 3.0
TROUBLESHOOTING GUIDE
LCD Message
What's Happening?
What Should Be Done?
****ERROR****
Low Voltage
Battery voltage dropped below
10.8V.
Check wiring for loose connection.
Test battery voltage under load - charge or
replace.
****ERROR****
Out Of Stroke
Jack has reached maximum
stroke length and is unable to lift.
Check disposition of jacks. Relocate the
coach.
****ERROR****
External Sensor
Bad connection or wiring from
the controller to the rear sensor.
Replace or repair connection to rear
remote sensor.
****ERROR****
Jack Time Out
Time limit exceeded for the
requested auto operation.
Check disposition of jacks.
****ERROR****
Auto Level Fail
Unable to auto level due to
uneven ground.
Check disposition of jacks. Relocate the
coach.
Unable to auto level due to zero
point being set incorrectly.
Reset zero point.
****ERROR****
Bad Calibration
Sensor calibration values are out
of range.
Reset zero point.
****ERROR****
Internal Sensor
Internal sensor problem.
Replace controller.
**PANIC STOP**
Function Aborted
The user pressed a button on the
touch pad during an automatic
operation.
Restart automatic operation and then
refrain from pressing any buttons on the
touch pad.