Ground control 2.0 troubleshooting guide – Lippert Components Ground Control 2.0 User Manual
Page 7

Rev: 11.26.2014
Page 7
Ground Control 2.0 Troubleshooting Guide
GROUND CONTROL 2.0
TROUBLESHOOTING GUIDE
Touch Pad Error Codes
NOTE: To clear Error Code, push "ENTER" - If error remains, the code will appear again.
LCD Display Text
What is Happening?
What Should Be Done?
"EXCESS ANGLE"
Unsecured controller.
Uneven or sloped site.
Check and secure controller placement.
Relocate the coach.
"FEATURE DISABLED"
Front of coach below level when
starting Auto Level process.
Raise front of coach above level and restart Auto
Level process.
"LOW VOLTAGE"
Battery voltage has dropped below
necessary operating range.
Check wiring - repair or replace.
Test battery voltage under load - charge or
replace.
"OUT OF STROKE"
Jack has reached maximum stroke
length.
Check disposition of jacks. Relocate the coach.
"EXTERNAL SENSOR"
Bad connection or wiring from the
controller to the rear sensor.
Replace or repair connection to rear remote
sensor.
"JACK TIME OUT"
Time limit exceeded for the
requested auto operation.
Check disposition of jacks.
"COMM ERROR"
Communication between controller
and touchpad has been lost.
Check harness for proper connections or
damage. Replace if necessary.
"CHECK STABILIZER"
Reminder for units equipped with JT
Strong Arm to lock the arms.
Lock the JT Strong Arm assemblies into
place and press FRONT and then REAR to
acknowledge.