Using the mic

Setting a high-pass filter

High-pass filters can be set by briefly pressing the noiseless high-pass filter push button ⑦. Settings are: linear, 12 dB / octave at

40 Hz, 6 dB / octave at 150 Hz and 6 dB / octave at 300 Hz.

Automatic attenuation function

The microphone will automatically adjust to the next higher attenuation level if it experiences clipping due to a high SPL. The microphone

enters and leaves the automatic attenuation mode by constantly pressing the pre-attenaution push button ⑨ for more than 2 seconds. The

microphone is set to automatic attenuation mode if the status indicator ③ is illuminated in red. Please note that the microphone will need

one second to adjust to the new attenuation level in the event of too high sound pressure levels.

Pre-attenuation indications

The currently active pre-attenuation setting is illuminated in white.

Setting a pre-attenuation level

Pre-attenuation levels can be set by briefly pressing the noiseless pre-attenuation push button

. Settings are: 0 dB, -6 dB, -12 dB

and -18 dB. Pre-attenuation is used in extremely high SPL environments in order to prevent clipping of the microphone, mixer and other

audio equipment.