3 operation direction – LABEC H-DW-HW50 User Manual
Page 8

3 Operation Direction
3.1
Use at the first time
Advise to use the warm water and little scour to clean the freezer,and use the
water to clean,then dry it.
To adjust the freezer at –40ºC,To cnnect the power,The compressor startup after
3minutes.30minutes later,The freezer temperature drop obviously,it mean the
refrigeration system is normal.We advise to adjust the temperature at -35ºC at
first,After stop the machine,Then set as -40ºC
To put the goods in the freezer after the temperature drop.
To save the power,Please don’t often open and close the door
3.2
Adjust the temperature
Keyboard functions:
1、Press "SET" 3seconds,will display as “F01”;
2、Use ▲and▼ to consult (F01、F02、F03);
3、Press "SET" to enter figures
4、Use▲ and ▼to add or reduce the figures.
5、press 'RST" to keep the change figures and back out.
Times
Figures range
Windows
default
Introduction
F01
-86~ -10
-80ºC
Temperature setting point
F02
1ºC~20ºC
1ºC
Compressor temperature
Boot back to poor(it mean
inside freezer
temperature >F01+F02 will
start cooling. )
F03
1ºC~20ºC
1ºC
Compressor temperature
Down to poor(it mean inside
freezer temperature
will end cooling. )