beautypg.com

Ii - specifications – LAARS IGI-180C-5(N,X) - Service Manual User Manual

Page 10

background image

II - SPECIFICATIONS

- GENERAL

Safety devices

Appliance - AC 120 Volts - 60Hz. 15A - Dedicated

Remote control DC 12 Volts (Digital)

Flame failure - Flame rod

Boiling protection - 203°F

Remaining flame (OHS) 194°F bi-metal switch

Thermal fuse 264°F

Automatic frost protection - Bimetal sensor & anti-frost heaters

Combustion fan rpm check - Integrated circuit

Over current - Glass fuse (3 amp)

If remote fails or becomes disconnected unit defaults to

100°F with water flowing, this is an anti-scald feature.

Remote control cable

Non-polarized two core cable or low voltage thermostat wire

Clearances from combustibles

Top of heater 6"

(12" min. recommended for service)

Front of heater 6"

(24" min. recommended for service)

Sides of heater 2"

Back of heater 0"

Floor 12"

Vent/Air Intake 0"

10

This manual is related to the following products: