beautypg.com

Table for the choice of the injectors, 2h3+ i – CDA RC9321 User Manual

Page 39

background image

39

Table for the choice of the injectors

GB

Cat:

II

2H3+

I

NCREASE OF AIR NECESSARY FOR GAS COMBUSTION

(2 m

3

/h x kW)

BURNERS

Air necessary for combustion [m

3

/h]

Auxiliary (A)

2,00

Semi-rapid (SR)

3,50

Rapid (R)

6,00

Triple-ring

7,00

Oven (left)

7,40

Grill (left)

5,00

Oven (right)

4,40

Grill (right)

4,00

Auxiliary (A)

1,00

0,30

50

-

72 (X)

-

Semi-rapid (SR)

1,75

0,45

65

-

97 (Z)

-

Rapid (R)

3,00

0,75

85

-

115 (Y)

-

Triple-ring

3,50

1,50

95

-

135 (T)

-

Oven (left)

3,70

0,75

92

fully open

140

5

Grill (left)

2,50

-

80

fully open

120

4

Oven (right)

2,20

0,63

72

fully open

110

4

Grill (right)

2,00

-

70

fully open

105

2

Nominal

Power

[kW]

Reduced

Power

[kW]

Ø injector

[1/100 mm]

G 30 - 28-30 mbar

G 31 - 37 mbar

G 20

20 mbar

BURNERS

Ø injector

[1/100 mm]

Tube ring

opening

[mm]

Tube ring

opening

[mm]