beautypg.com

Conversion to natural gas or to lpg, Injectors replacement of top burners, Adjusting of the minimum of the top burners – CDA RC9321 User Manual

Page 38

background image

38

J

Fig. 44b

Injectors replacement of
top burners

Every cooker is provided with a set of injec-
tors for the various types of gas.

Injectors not supplied can be obtained
from the After-Sales Service.

Select the injectors to be replaced accord-
ing to the table at page 39.
The nozzle diameters, expressed in hun-
dredths of a millimetre, are marked on the
body of each injector.

To replace the injectors proceed as follows:

Remove the grids and extract the burner
bodies.

Using a wrench, substitute the nozzle
injectors “J” (Figs. 44a - 44b) with those
most suitable for the kind of gas for
which it is to be used (see “Table for the
choice of the injectors”).

The burners are constructed in such a
way so as not to require the regula-
tion of the primary air.

Adjusting of the minimum
of the top burners

Considering that in the minimum position
the flame must have a length of about 4
mm and must remain lit even with a quick
turn from the maximum position to that of
minimum.

The flame adjustment is done in the follow-
ing way:
– Turn on the burner
– Turn the tap to the MINIMUM position
– Take off the knob
– With a thin screwdriver turn the screw

F

until adjustment is correct (fig. 45).

Normally for LPG, tighten up the regu-
lation screw.

J

Fig. 44a

Conversion to Natural Gas or to LPG

F

Fig. 45