3. Press

C to change the flashing screen content in the sequence shown below to

select the other settings.

Seconds

12/24-Hour

Format

Hour

Minutes

DST

Month

Year

City Code

Day

Illumination

Duration

4. When the setting you want to change is flashing, use

D or B to change it as

described below.

Change the city code

Toggle the DST setting between
Daylight Saving Time (on) and
Standard Time (OFF).

Use

D (east) and B

(west).
Press

D.

Screen:

To do this:

Do this:

E-11

5. Press

A to exit the setting mode.

• The day of the week is displayed automatically in accordance with the date (year,

month, and day) settings.

Screen:

To do this:

Do this:

Toggle between 12-hour (12H) and
24-hour (24H) timekeeping
Reset the seconds to 00

Change the hour and minutes

Change the year, month, or day

Toggle the face illumination duration
between 1.5 seconds (LT1) and three
seconds (LT3)

Press

D.

Press

D.

Use

D (+) and B (–).

Press

D.

E-12

Daylight Saving Time (DST)

Daylight Saving Time (summer time) advances the time setting by one hour from
Standard Time. Remember that not all countries or even local areas use Daylight
Saving Time.

To change the Daylight Saving Time (summer time) setting

1. In the Timekeeping Mode, hold down

A for about three

seconds until the currently selected city code flashes in
the right digital dial. This is the setting mode.

2. Press

C. This will display the DST setting screen.

3. Use

D to toggle the DST setting on (on) and off (OFF).

• The default DST setting is off (OFF).

4. When the setting you want is selected, press

A to exit

the setting mode.

• The DST indicator appears to indicate that Daylight

Saving Time is turned on.

DST indicator

E-13

12-hour and 24-hour timekeeping

• With the 12-hour format, the PM indicator appears in the left digital dial for times in the

range of noon to 11:59 p.m. and no indicator appears for times in the range of
midnight to 11:59 a.m.

• With the 24-hour format, times are displayed in the range of 0:00 to 23:59, without

the PM indicator.

• The 12-hour/24-hour timekeeping format you select in the Timekeeping Mode is

applied in all other modes.

E-14

Stopwatch

You can use the stopwatch to measure elapsed time, lap
times and split times. If you specify a distance value, the
stopwatch also will calculate and display speeds.

• The digital display range of the stopwatch is 99 hours,

59 minutes, 59.999 seconds. The stopwatch continues
to run until you stop it. If it reaches the above limit, it will
restart the time measurement from zero.

• The stopwatch operation continues even if you exit the

Stopwatch Mode. If you exit the Stopwatch Mode while a
stopwatch operation is in progress, the segments along
the top of the right digital dial (right dial display
segments) will indicate the seconds of the current time.
Each segment represents one second. This is to let you
know that a stopwatch operation is in progress.

• All of the operations in this section are performed in the

Stopwatch Mode, which you enter by pressing

C (page

E-7).

Speed hand

Right dial
display
segments

E-15

Important!

• Check to make sure that the speed hand is not moving before you perform any

Stopwatch Mode button operation.

Specifying a Distance Value

You can use the procedure below to specify a distance value, if you want. If you
specify a distance value, the watch will calculate and indicate speed for certain
stopwatch operations.

• The distance value represents kilometers, miles, or any other distance unit you want.

Specifying a distance value of 10.0, for example, can mean 10.0 kilometers or 10.0
miles.

• No speed calculation is performed when 0.0 is specified as the current distance

value.

• For lap time readings, you can specify either the lap distance (when all the laps are

the same distance) or the total race distance.

• For split time readings, you can specify the total race distance only. Though the

watch will indicate a speed each time you take a split reading, they will be based on
the total race distance, and so they will not indicate actual intermediate split speeds.

E-16

To specify a distance value

1. In the Stopwatch Mode, make sure the stopwatch is

stopped and reset to all zeros.

• If you need to reset the stopwatch to all zeros, press A.

2. Hold down

A for about three seconds until the current

distance value setting flashes in the left digital dial.

• This is the distance value setting mode.

3. Press

C to move the flashing between the values on

the left side and right side of the distance value decimal
point.

4. While a distance value is flashing, use

D (+) and B (–)

to change it.

• You can specify a distance value in the range of 0.1 to

99.9.

5. After specifying the distance value you want, press

A

to exit the setting mode.

E-17

How speed is indicated

• While an elapsed time measurement operation is being

performed in the Stopwatch Mode, the watch will
indicate a speed value, which is calculated based on the
distance you specified and the elapsed time.
The speed value is indicated as described below.
Speed hand: Up to 100
Right dial display segments: 100 unit
A 1000 indicator points to 1000 (located to the right of
the right dial display segments) when the speed value is
between 1000 and 1998.

• The speed hand indicates speed values less than 100.

Only even-numbered values are indicated.

• Speed can be indicated from 0 to 1998. OVER is indicated

by the speed hand when the speed exceeds 1998.

Example:
When the speed value is 1,740.
Speed hand: Indicates 40.
Right dial display segments: Indicate 700.
1000 indicator: Displayed

Segments
(100 unit)

OVER

Speed hand
(Up to 100)

1000 indicator

E-18

Time Measurement

You need to specify either lap time (page E-20) or split time (page E-22) measurement
before you start a stopwatch operation.

• If you want to measure total elapsed time, select split time measurement.

To specify lap time or split time readings

1. In the Stopwatch Mode, make sure the stopwatch is stopped and reset to all zeros.

• Make sure that

LAP

(lap times) or

SPL

(split times) is shown in the left digital dial.

• If you need to reset the stopwatch to all zeros, press A.

2. You can toggle between

LAP

(lap times) and

SPL

(split times) by pressing

A.

A

E-19

Elapsed Time Measurement
Use the following procedure to measure elapsed time, without taking lap time or split
time readings.

To perform elapsed time measurement

Select split time (

SPL

) measurement and then perform the following button operations.

D Start ➝ D Stop ➝ A Reset
• If you have a distance value (page E-15) specified for the current elapsed time

measurement, the right dial display segments and speed hand will indicate the
speed when you press

D to stop the elapsed time operation.

• After pressing D to stop an elapsed time operation, you could press D again to