beautypg.com

Wiring cont – Crimestopper Security Products EZ-95FM User Manual

Page 10

background image

10

Momentary

Switch

New TURBO TIMER MODE

GREEN

EXPANSION (Default)

OEM INTERFACE

GREEN

GREEN

(Not included)

(Aux Channel

AFTERMARKET

1 sec. (-) pulse

FACTORY KEYLESS

Output)

ALARM / KEYLESS

MODULE

3 Consecutive

(-) pulses

1 MODE

2 MODE

3 MODE

WIRING Cont.


PIN 3: GREEN: (-) START ACTIVATION INPUT, OEM INTERFACE or TURBO TIMER INPUT
See descriptions & diagrams below.


Mode (1) [Default (-) Neg. Start Activation] This wire
allows a host (or parent) alarm’s or keyless entry system
to activate a Remote Start by sending a 1-Second
Negative signal to the Green input wire to trigger a remote
engine start or stop. Connect the Green wire to the host
system’s Auxiliary channel output wire.

Mode (2) [Alternate OEM Interface] This mode allows the
system to Remote Start or Stop when 3 successive
Negative pulses are sent to the Green input wire.
Connect the Green input wire to the Negative lock signal
wire of the factory system. If your Factory OEM system
does not have this type of signal, then a relay is required.

Mode (3) [TURBO TIMER INPUT [No programming
required] this wire allows the system to keep a vehicle
running for 1-5 minutes [selectively] after removing the
key. This mode requires the use of a momentary switch
that is not included with the kit. Connect a 2-pole
momentary switch with one side to chassis Ground and
the other side to the Green input wire. If you own a turbo
or turbo diesel vehicle, you can now allow the
EZEESTART system to keep your engine running for 1-5
minutes after exiting/locking your vehicle to cool-down
without the need for an external “Turbo Timer”.

NOTE: The turbo timer button will also trigger a remote start if it is inadvertently pressed when the vehicle is

not running. Please note this when installing the button and choose a location out of harm’s way.