beautypg.com

Cleaning, maintenance, and lubrication, Safet y op era tion m aintenance setu p – Chicago Electric Electric Impact Wrench 68099 User Manual

Page 10

background image

Page 10

For technical questions, please call 1-800-444-3353.

Item 68099

SAFET

y

Op
ERA
TION

M

AINTENANCE

SETU
p

Maintenance and Servicing

procedures not specifically explained in this manual must

be performed only by a qualified technician.

TO pREVENT SERIOUS INJURy

REVENT SERIOUS INJUR

REVENT SERIOUS INJUR FROM ACCIDENTAL

yy

OpERATION:

Release the Trigger and unplug the tool from its electrical outlet

before performing any procedure in this section.

TO pREVENT SERIOUS INJURy

REVENT SERIOUS INJUR

REVENT SERIOUS INJUR FROM TOOL FAILURE:

yy

Do not use damaged equipment. If abnormal noise or vibration

occurs, have the problem corrected before further use.

Cleaning, Maintenance, and Lubrication

1.

BEFORE EACH USE, inspect the general

condition of the tool. Check for:
• loose hardware,
• misalignment or binding of moving parts,
• cracked or broken parts,
• damaged electrical wiring, and
• any other condition that may

affect its safe operation.

2.

AFTER USE, wipe external surfaces

of the tool with clean cloth.

3.

WARNING! If the supply cord of this

power tool is damaged, it must be replaced

only by a qualified service technician.

4.

CARBON BRUSH MAINTENANCE.

The carbon brushes may require maintenance when

the motor performance of the tool decreases or

stops working completely. To maintain the brushes:
a. Remove the Carbon Brush Cover on

each side of the motor housing.

b. Remove the carbon brushes from the

housing.

Keep track of which orientation

the old carbon brushes were in to prevent

needless wear if they will be reinstalled.

c. If either carbon brush is worn down by

more than 1/2, replace them both.

d. To clean old carbon brushes before reusing them,

rub the contact areas with a pencil eraser.

e. Reinsert the old carbon brushes in the

same orientation to reduce wear.

f. When installing, make sure the carbon portions

of the brushes contact the motor armature,

and that the springs face away from the motor.

Also, make sure the springs operate freely.

g. Replace the Carbon Brush

Covers. Do not overtighten.

Note: New carbon brushes tend to spark when first used

New carbon brushes tend to spark when first used

until they wear and conform to the motor’s armature.