beautypg.com

Specifications – Culligan Water Filter User Manual

Page 4

background image

Culligan Medallist Series

Water Conditioners with Timeclock or Soft-Minder

®

Meter

8” Model

30 Model

45 Model

Control Valve Type

5-cycle Reinforced

5-cycle Reinforced

5-cycle Reinforced

Thermoplastic

Thermoplastic

Thermoplastic

Overall Conditioner Height

51 in.

49 in.

63 in.

1,295 mm

1,245 mm

1,600 mm

Media Tank Dimensions

8 x 44 in.

10 x 40 in.

10 x 54 in.

(Dia. x Ht.)

203 x 1,118 mm

254 x 1,016 mm

254 x 1,372 mm

Salt Storage Tank Dimensions

16 x 43 in.

18 x 43 in.

18 x 43 in.

(Dia. x Ht.)

457 x 1,092 mm

457 x 1,092 mm

457 x 1,092 mm

18 x 43 in.
457 x 1,092 mm

Exchange Media, Type & Quantity Cullex

®

Media, 0.7 ft

3

Cullex Media, 1.0 ft

3

Cullex Media, 1.5 ft

3

Underbedding, Type & Quantity

Cullsan

®

Underbedding,

Cullsan Underbedding,

Cullsan Underbedding,

6 lb.

8 lb.

8 lb.

Exchange Capacity @ Salt

18,300 gr @ 4 lb.

20,200 gr @ 5 lb.

24,900 gr @ 6 lb.

Dosage Per Recharge

1

25,100 gr @ 9 lb.

29,400 gr @ 11 lb.

39,200 gr @ 14 lb.

27,500 gr @ 12 lb.

35,000 gr @ 17 lb.

43,500 gr @ 20 lb.

Efficiency at Rated Salt Dosage

5

4 lb. salt dosage:

5 lb. salt dosage

6 lb. salt dosage

4570 gr./lb.

4050 gr./lb.

4150 gr./lb.

Freeboard to Media

2

20.5 - 21.5 in.

17 - 18 in.

19.75 - 21.75 in.

Freeboard to Underbedding

3

42.0 - 42.5 in.

39.6 - 40.1 in.

53.8 - 54.3 in.

Salt Storage Capacity

250 lb. or 375 lb.

375 lb.

375 lb.

Rated Service Flow @ Pressure Drop

5.9 gpm @ 12 psi

7.2 gpm @ 12 psi

7.0 gpm @ 13 psi

Total Hardness, Maximum

75 gpg

99 gpg

99 gpg

Total Iron, Maximum (dissolved)

5 ppm

5 ppm

5 ppm

Hardness to Iron Ratio, Minimum 8 gpg to 1 ppm

8 gpg to 1 ppm

8 gpg to 1 ppm

140 mg/L to 1 mg/L 140 mg/L to 1 mg/L 140 mg/L to 1 mg/L

Operating Pressure

20 - 125 psi

20 - 125 psi

20 - 125 psi

140 - 860 kPa

140 - 860 kPa

140 - 860 kPa

Operating Pressure (Canada)

20 - 90 psi

20 - 90 psi

20 - 90 psi

140 - 620 kPa

140 - 620 kPa

140 - 620 kPa

Operating Temperature

33 - 120°F

33 - 120°F

33 - 120°F

1 - 50°C

1 - 50°C

1 - 50°C

Electrical Requirements

24V/60 Hz

24V/60 Hz

24V/60 Hz

Electrical Power Consumption,

3 Watts/35 Watts

3 Watts/35 Watts

3 Watts/35 Watts

Min./Max.
Drain Flow, Maximum

4

1.1 gpm

2.0 gpm

2.1 gpm

Recharge Time, Average

85 min.

64 min.

64 min.

Recharge Water Consumption

23.3 gal.

61 gal.

65 gal.

1 Capacities and corresponding salt dosages pertain to low hardness waters. Capacities given per recharge
2 Measured from top of media to top of inlet fitting (backwashed and drained)
3 Measured from top of underbedding to top of inlet fitting
4 Backwash at 120 psi (830 kPa)
5 Efficiency rating only valid at stated salt dosage on softminder models and is efficiency rated according to ANSI/NSF
Standard 44

2

Specifications