Setting the Microprocessor

The microprocessor senses when it is installed as a Soft-Minder

®

control. Adding or removing

any connection to the board will automatically reset the microprocessor to the factory
settings.

Step 1 – Programming Time of Day
Press the “STATUS” key.
The display will blink “tod” for 3 seconds and then
change to time of day with the “minutes” digits blinking.
Adjust the “minutes” digits with the “+” or “-” keys.
Press the “REGEN” key to blink the “hours” digits.
Adjust the “hours” digits with the “+” or “-” keys.
Press the “REGEN” key to cycle back to “minutes”
Note: The “hours” setting scrolls through 1-12 AM and 1-12 PM.
Make sure the proper AM or PM indicator is shown when setting the time.

Step 2 – Programming Regeneration Time
Press the “Status” key after setting the time of day.
The display will blink “tor” for 3 seconds and then
change to the time setting with the “ones” digit blinking.
Adjust regeneration time as time of day above.
Note: This option will not show if the “dIP 2” option is set
to immediate

Step 3 – Programming Salt Dosage
Press the “Status” key after programming regeneration
time. The display will blink “SLtP” if set to English or
“SLtG” if set to Metric for 3 seconds and then display
the salt dosage.
Adjust the setting with the “+” or “-” key (3-24 lbs.)
(1-10 kgs.)
Note: This option will not show if the control is set to Filter mode.

Step 4 – Programming Backwash Time
Press the “Status” key after programming salt dosage.
The display will blink “bw” for 3 seconds and then
display the backwash time in minutes.
Adjust the setting with “+” or “-” key. (1-40 minutes)

Programming

i2:00

PM

2:00

AM

i0

i0

9