beautypg.com

Installing, Caution, Warning – Desa Tech CG3630PV User Manual

Page 17

background image

17

101992

Tee Joint

Pipe

Nipple

Cap

3" Minimum

Sediment

Trap

Gas
Regulator

From

External Regulator

(11" W.C.** to

14" W.C.

Pressure)

A.G.A. Design-Certified
Manual Shutoff Valve
With 1/8" NPT Tap*

Approved Flexible
Gas Hose (if allowed
by local codes)

CAUTION

Avoid damage to regulator. Hold gas regulator with wrench when
connecting it to gas piping and/or fittings.

Figure 14 - Gas Connection

* Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer.
See Accessories, page 31.
** Minimum inlet pressure for purpose of input adjustment.

INSTALLING

Continued

Pressure Testing gas Supply Piping system

Test Pressures In Excess Of 1/2 PSIG

1. Disconnect heater and its individual manual shutoff valve from gas supply

piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2. Cap off open end of gas pipe where manual shutoff valve was connected.

WARNING

Never use an open flame to check for a leak. Apply a mixture of
liquid soap and water to all joints. Bubbles forming show a leak.
Correct all leaks at once.

WARNING

Test all gas piping and connections for leaks after installing or
servicing. Correct all leaks at once.

CAUTION

Make sure external regulator has been installed between propane/
LP supply and heater. See guidelines under

Connecting to Gas

Supply, page 15.

CHECKING GAS CONNECTIONS

Continued

This manual is related to the following products: