5 slc 8dmt: physical description – Cisco 6200 User Manual
Page 29
78-5296-02
10/02/98
Hardware Description
1
Cisco 6200 User Guide
1-29
•
Number of upstream cells received with invalid header checksum
•
Number of errored seconds (this is the number of seconds in which at least one DMT-layer CRC
error, loss of signal, or severely errored frame is observed), both upstream and downstream
In addition, the SLC 8DMT reports the following fault indications:
•
Far end LPR
•
Near end LOS
•
Near end LOF
•
Near end loss of cell delineation (LOCD)
1.5.5 SLC 8DMT: Physical Description
Up to ten SLCs can be installed in a Cisco 6200 cabinet. The slots assigned to the SLCs are slot 5
through slot 14.
The card’s faceplate is labeled SLC 8DMT. The faceplate (Figure 1-13) includes a reset switch and
LED indicators.