Cisco 6200 User Manual
Page 25
78-5296-02
10/02/98
Hardware Description
1
Cisco 6200 User Guide
1-25
Table 1-9
SLC 8CAP LEDs
LED
Color
Condition Indicated
POWER
Green
The SLC is receiving power.
READY
Green
Yellow
Off
The SLC is experiencing no problems.
At least one port on the SLC is in line test mode.
The SLC is not communicating with the MPC. This is the case when
• The SLC is initializing.
• The SLC has a hardware problem. If the READY LED is off for an extended
period when the POWER LED is on, see the Cisco 6200 User Guide for
instructions on troubleshooting the SLC.
PRIME
Green
The SLC is using the primary (A) bus to move information across the backplane.
SEC
Green
The SLC is using the secondary (B) bus to move information across the backplane.
(Redundant systems only.)
Ports 0 to 7
Green
The following conditions exist:
• The port is receiving the upstream heartbeat message regularly.
• The heartbeat message indicates the CAP PIM has HEC alignment in the
downstream direction.
• The SLC has HEC alignment in the upstream direction.
• The modems on both sides have negotiated the loop rates.
The port LEDs remain lit (green) in the presence of occasional minor alarms.
Flashing
green
The loop is rate-adapting (training).
Off
One of the following conditions exists:
• The port is experiencing an intrusive line quality test.
• The port is experiencing an intrusive CAP hardware test.
• The port is disabled or is not configured.