INSTALLATION/REMOVAL

3-7

3.3.4 Removing from the 7C04 or 7C04-R Workgroup

SmartSwitch

The 7F06-02 Module, inserted in the 7C04 or the 7C04-R
Workgroup SmartSwitch, can be removed whenever necessary.
Follow the steps below and refer to the appropriate figure to
remove the module.

Note:

Before removing the 7F06-02 module, attach the wrist strap
included with the SmartSwitch or SmartSwitch module by
following the instructions printed on the package.

1. Use a slotted screwdriver to loosen the two screws that secure the

module to the chassis.

2. Locate the two ejector tabs on the module (below the screws on the left

and right end of the module).

3. Simultaneously press left on the left ejector tab and right on the right

ejector tab until the module ejects from the backplane.

4. Grasp both ejector tabs and carefully slide the module out of the

chassis.

Figure 3-6. Removing the 7F06-02 Module from the 7C04 Workgroup