Network requirements, 1 fpim module specifications, 1 fpim-00 and fpim-01 – Cabletron Systems 7F06-02 User Manual
Page 12: Chapter 2 network requirements, 1 fpim module specifications -1, 1 fpim-00 and fpim-01 -1, Appendix a
![background image](/manuals/68055/12/background.png)
2-1
CHAPTER 2
NETWORK REQUIREMENTS
Before installing Cabletron Systems 7F06-02 Module, review the
network requirements outlined in this chapter. All requirements
included in this chapter should be met to ensure satisfactory
performance of the 7F06-02 Module. Failure to do so may result in
unsatisfactory network performance.
Appendix A
2.1 FPIM MODULE SPECIFICATIONS
This module uses Fiber Port Interface Modules (FPIM) to provide
front panel cable connections. The FPIMs are user-installable. See
Section 3.2
2.1.1 FPIM-00 and FPIM-01
The FPIM-00 and FPIM-01 provide a multimode fiber connection.
The FPIM-00 uses a MIC style connector and the FPIM-01 uses an
SC type connector. The specifications for both devices are listed in
Table 2-1.
Table 2-1. FPIM-00 and FPIM-01 Specifications
Parameter
Typical
Value
Worst
Case
Worst
Case
Budget
Typical
Budget
Receive
Sensitivity
-30.5 dBm
-28.0 dBm
—
—
Peak Input
Power
-7.6 dBm
-8.2 dBm
—
—