beautypg.com

Dutchwest natural vent gas heater – CFM Corporation 2467 User Manual

Page 17

background image

17

Dutchwest Natural Vent Gas Heater

30002008

Pilot Hood

Pilot
Bracket

CO105a

Fig. 31 Remove pilot hood.

Index Tab

Snap Ring

Allen Wrench

CO106a

Fig. 32 Remove pilot orifice.

Remove pilot orifice with allen wrench. (Fig. 32)

Install the conversion orifice.

Reinstall pilot hood. Be sure to align hood with

index tab.

16. Adjust air shutter on the burner. The air shutter is

located on the bottom of the burner on the left. (Fig.
46) Loosen the two nuts holding the shutter in place.
On natural gas units, the shutter is shipped fully
closed. To convert to LP, reset the shutter as speci-
fied in Table 2. (Fig. 34) On propane unit the shutter
is set at 1/8” or 3/8” opening depending on rating
plate serial number. To convert to natural gas, the
shutter should set to fully closed. Refasten the two
nuts.

Front Injector Air Inlet

Air Shutter

Burner

Air Shutter

Rear
Injector Air
Inlet -
Covered

Configuration for
Stove with Serial
#’s up to #5250

Configuration for Stoves with
Serial #’s Starting at 5251

ST718

Fig. 33 Natural gas air shutter setting.

1/8"

3/8"

Air Shutter
(LP Position)

Air Shutter
(LP Position)

Configuration for
Stove with Serial #’s
up to #5483

Configuration for Stoves with
Serial #’s Starting at #5484

ST726

Fig. 34 LP air shutter settings.

Fig. 35 Remove and replace injector orifices.

90¡

Left Burner Leg

Injector Orifices

ST353a

NOTE: Be sure burner leg remains at a 90

°

angle to

firebox base after conversion.

17. Replace burner. Slide the burner in at an angle with

left side lower than the right side. Slide the left side
onto the injectors, making sure the burner leg
remains at a 90

°

angle to the base. Lower the right

hand side down in to place. Make sure the burner is
as far left as possible and the injector shoulders are
inside the burner.

NOTE: It is very critical to keep the left burner leg,

which holds the injectors, at a 90

°

angel to the base.

(Fig. 35) This keeps the orifices aligned with the
tubes inside burner. Failure to do so could affect the
flame appearance and performance of the unit.

18. Place conversion label on valve.

19. Reinstall the right and left log bracket assembly.

20. Replace logs.

21. Replace glass and stove front.

22. Check manifold pressure.

Conversion is complete.

This manual is related to the following products: