beautypg.com

Specifications – Crown Audio CTs 2-Channel User Manual

Page 39

background image

P O R T A B L E P A

• 39

www.crownaudio.com

SPECIFICATIONS

Performance

Sensitivity (for full rated power at 4 ohms):
1.25 Vrms.

Frequency Response (at 1 watt, 22 Hz to
20 kHz): +0 dB, –1 dB.

Signal-to-Noise Ratio (20 Hz to 20 kHz,
inputs terminated):
A-weighted, below rated power: > 100 dB.
No weighting, below rated power: > 95 dB.

Total Harmonic Distortion (THD): < 0.5%.

Intermodulation Distortion (IMD):
(60 Hz and 7 kHz at 4:1) from full rated
output to –40 dB: < 0.3%.

Damping Factor (8 ohm) 10 Hz to 400 Hz:
>200.

Crosstalk (below rated power):
at 1 kHz: –75 dB.
at 20 kHz: –59 dB.

Input Impedance (nominal): 20 kilohms bal-
anced, 10 kilohms unbalanced.

Output Power: See power charts.

Load Impedance:
XLS 202, 402, 602, 802: 4 to 8 ohms per
channel in Stereo, 8 ohms in Bridge Mono.
XLS 5000: 2 to 8 ohms per channel in Stereo,
4 to 8 ohms in Bridge Mono.

AC Line Voltage and Frequency Confi gura-
tions Available (±10%):
120 VAC 60 Hz, 100
VAC 50/60 Hz, 220 VAC 50 Hz, and 230-240
VAC.

Controls

Level: Two front-panel rotary level con-
trols, one for each channel.

Power: Front-panel switch; on when in the
IN position.

Circuit Breaker: Back-panel breaker provides
overload protection.

Mode Switch: Back-panel switch selects Dual
or Bridge-Mono mode.

Indicators

Signal Presence Indicators: Two green LEDs,
one for each channel, illuminate when the
channel’s input signal exceeds –40 dBu.

Clip Indicators: Two red LEDs, one for each
channel, illuminate when the channel’s output
is being overdriven.

Power Indicator: Blue LED indicates ampli-
fi er has been turned on and AC power is
available.

Fault Indicator: Two red LEDs, one for each
channel, illuminate when amplifi er is in
protect mode. Also illuminates briefl y during
normal power-up when amplifi er is fi rst
switched on.

Input/Output

Input Connectors: One per channel; back-
panel three-pin female XLR input connec-
tors.

Output Connectors: Two 4-Pole Speakon

®

Output Connectors accept 2-pole or 4-pole
Speakon

®

connectors. The top Speakon

connector is wired for both channels so it can
be used for bridge-mono wiring or for stereo
wiring of two speakers to a single Speakon
connector.

One pair of back-panel binding posts per
channel; accepts banana plugs or bare wire.
(European models do not accept banana
plugs.)

Protection

XLS Series amplifi ers provide extensive pro-
tection and diagnostic capabilities, including
output current limiting, DC protection, circuit
breaker, and thermal protection.

Construction

Ventilation: Flow-through ventilation from
front to back.

Cooling: Internal heat sinks with forced-air
cooling for rapid, uniform heat dissipation.

Air Volume Requirements (per minute per
unit):
80.15 ft³ (2.27 m³).

Dimensions (XLS 202, 402, 602, 802): EIA
Standard 19-inch (48.3-cm) rack mount
width (EIA RS-310-B), 3.5-inch (8.9-cm)
height and 15.2-inch (38.6-cm) depth.

Dimensions (XLS 5000): EIA Standard
19-inch (48.3-cm) rack mount width (EIA
RS-310-B), 5.25-inch (13.3-cm) height and
15.5-inch (39.5-cm) depth.

Weight

Net Weight:
XLS-202: 23.0 lb (10.4 kg)
XLS-402: 25.7 lb (11.7 kg)
XLS-602: 29.0 lb (13.2 kg)
XLS-802: 35.5 lb (16.1 kg)
XLS-5000: 62.0 lb* (27.7 kg)*

Shipping Weight:
XLS-202: 28.0 lb (12.7 kg)
XLS-402: 30.7 lb (13.9 kg)
XLS-602: 34.0 lb (15.4 kg)
XLS-802: 40.5 lb (18.4 kg)
XLS-5000: 74.0 lb* (33.6 kg)*

Regulatory Certifications

Other Applications

T

he XLS Series of power amplifiers from Crown represents a new era in affordable, quality power
amplification. The line consists of five models in a uniform, rugged 2U chassis (3U for the XLS

5000), incorporating the best of tried-and-true design principles and innovative features.

except

XLS 5000

XLS 5000

only

except

XLS 5000

except

XLS 5000

*Preliminary

3/08 139436-3B