DesignLine Recessed Door Contact Installation Instructions

Figure 2: Mounting

Note: This is only one mounting option. You should select

the best mounting method based on the application.

3. Using an 7/8 in. drill bit, slowly drill the first hole for the

magnet. The TX-1510-01-1 was specifically designed to

be slightly larger than an 7/8 in. hole so you will need to

carefully drill to fit by slowly routing the hole little by little to

ensure a snug fit.

4. Using a 7/8 in. drill bit, drill the mating hole for the

transmitter and use either the standard flush-mount cap

and insert the transmitter for a snug fit, or use the flanged

cap and use the screws provided to mount the transmitter

to the door frame.

Enrolling

The following section describes general guidelines for
programming (learning) the sensor into the panel’s memory.
Refer to you panel documentation for complete programming

details.

To program (learn) the contact into the panel, do the following:

1. Unscrew the top of the contact.

2. Set the panel into program mode.

3. Refer to your panel documentation for instructions for

learning sensors.

4. Press and release the tamper switch on the top of the

contact circuit board (Figure 1 on page 1)until the panel

responds.

5. Replace the contact top.

6. Exit program mode.

Specifications

Battery

CR2032, 3 VDC, 225 mAh, Lithium Coin Cell

Typical battery life

5 to 8 years

Transmitter frequency 319.508 MHz (crystal-controlled)

Transmitter frequency
tolerance

± 8 kHz

Bandw idth

24 kHz

Modulation type

Amplitude shift key (ASK)

Unique ID codes

16 million

Peak field strength

Typical 35,000 uV/m at 3 m

Supervisory interval

64 minutes

Operating temperature 10 to 120°F (-12 to 49°C)

Enclosure

PC-540

Weight

0.63 oz. (18 g)

Dimensions (L x W x
H)

1.70 x 1.10 x 0.91 in. (4.32 x 2.76 x 2.32 cm)

Color

Belgian gray

Regulatory information

FCC compliance

This device complies w ith part 15 of the FCC
rules. Operation is subject to the follow ing
conditions:

1. This device may not cause harmful
interference.

2. This device must accept any interference
received, including interference that may cause
undesired operation.

Changes or modifications not expressly approved
by the party responsible for compliance could
void the user’s authority to operate the
equipment.

FCC ID: B4Z-TX-1510-01

Industry Canada ID: 1175C-TX151001

Contact information

www.utcfireandsecurity.com

or

www.interlogix.com

For customer support, see

www.interlogix.com/customer-

support

© 2012 UTC Fire & Security Americas Corporation, Inc.

Interlogix is part of UTC Climate Controls & Security, a unit of