Enrolling, Specifications, Regulatory information – Interlogix DesignLine Recessed Door Contact User Manual
Page 2: Contact information
2
DesignLine Recessed Door Contact Installation Instructions
Figure 2: Mounting
Note: This is only one mounting option. You should select
the best mounting method based on the application.
3. Using an 7/8 in. drill bit, slowly drill the first hole for the
magnet. The TX-1510-01-1 was specifically designed to
be slightly larger than an 7/8 in. hole so you will need to
carefully drill to fit by slowly routing the hole little by little to
ensure a snug fit.
4. Using a 7/8 in. drill bit, drill the mating hole for the
transmitter and use either the standard flush-mount cap
and insert the transmitter for a snug fit, or use the flanged
cap and use the screws provided to mount the transmitter
to the door frame.
Enrolling
The following section describes general guidelines for
programming (learning) the sensor into the panel’s memory.
Refer to you panel documentation for complete programming
details.
To program (learn) the contact into the panel, do the following:
1. Unscrew the top of the contact.
2. Set the panel into program mode.
3. Refer to your panel documentation for instructions for
learning sensors.
4. Press and release the tamper switch on the top of the
contact circuit board (Figure 1 on page 1)until the panel
responds.
5. Replace the contact top.
6. Exit program mode.
Specifications
Battery
CR2032, 3 VDC, 225 mAh, Lithium Coin Cell
Typical battery life
5 to 8 years
Transmitter frequency 319.508 MHz (crystal-controlled)
Transmitter frequency
tolerance
± 8 kHz
Bandw idth
24 kHz
Modulation type
Amplitude shift key (ASK)
Unique ID codes
16 million
Peak field strength
Typical 35,000 uV/m at 3 m
Supervisory interval
64 minutes
Operating temperature 10 to 120°F (-12 to 49°C)
Enclosure
PC-540
Weight
0.63 oz. (18 g)
Dimensions (L x W x
H)
1.70 x 1.10 x 0.91 in. (4.32 x 2.76 x 2.32 cm)
Color
Belgian gray
Regulatory information
FCC compliance
This device complies w ith part 15 of the FCC
rules. Operation is subject to the follow ing
conditions:
1. This device may not cause harmful
interference.
2. This device must accept any interference
received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved
by the party responsible for compliance could
void the user’s authority to operate the
equipment.
FCC ID: B4Z-TX-1510-01
Industry Canada ID: 1175C-TX151001