Technical specifications, Electrical, Environmental – Interlogix VTP-AR6 Series User Manual
Page 8
![background image](/manuals/679284/8/background.png)
8 of 11
P/N 1069681 • REV 1.0 • ISS 14APR10
• If the picture is scrambled change the polarity of the twisted pair wires to the
corresponding terminal block.
Technical Specifications*
Electrical
Video Format
NTSC, PAL, SECAM
Frequency
20 Hz to 6 MHz
Adjustment Automatically
controlled by internal microprocessor
Coax 75
Ohm
Twisted Pair
100 Ohms +/- 20%, 24 AWG min., unshielded Category 2-7 up to 750 ft.
(228m)
CMRR 70
dB
Video Present
Green LED’s, one per channel
Power indicator
Red LED
Connectors
UTP inputs: Detachable terminal blocks, RJ-45 or Optional RJ-45 Adapter
(Included)
Video Outputs: BNC
Power: IEC380 AC power inlet (excluding GEC-4VARHUB-4)
Standard P1J DC inlet receptacle 2.1 x 5.5 mm, center positive (GEC-
4VARHUB-4)
Main AC Fuse
1 A at 115 VAC/3 A at 220 VAC, 5x20 mm, 8 channel models
1.5 A at 115 VAC/5 A at 220 VAC, 5x20 mm, 16 channel models
2 A at 115 VAC/5 A at 220 VAC, 5x20 mm, 32 channel models
A spare fuse is located inside the fuse holder.
Environmental
Humidity 0
to
95%,
noncondensing
Temperature
Operating: -10° to +50° C
Storage: -30° to +70° C