beautypg.com

Wiring technical notes – Interlogix VTP-AR6 Series User Manual

Page 4

background image

4 of 11

P/N 1069681 • REV 1.0 • ISS 14APR10

Wiring Technical Notes

These technical notes should all be considered prior to installing these devices.

• Use point to point unshielded twisted pair wire 24-16 AWG (0, 5-1, 3 mm)

stranded or solid, Category 2 or better.

• The video signal may coexist in the same wire bundle as other video,

telephone, data, control signals, or low-voltage power. You can run GE video
signals in or near electromagnetic fields (in accordance with National
Electrical Code, local or other local safety requirements).

• DO NOT USE SHIELDED TWISTED PAIR WIRE. Multi-pair (8 pair or more) wires

with an overall shield are fine.

• DO NOT USE UN-TWISTED WIRE.

• DO NOT place a transmit and a receive signal in the same wire bundle. It

may cause interference.

• DO NOT send Up-the-Coax Pan/Tilt/Zoom signals through active (amplified)

GE transmitters or receivers. Passive GE transceivers can transmit video and
Up-the-Coax P/T/Z control signals up to 750 ft. (228 m).

• We recommend using short 18 AWG solid wires for ground connections.

• GE VPD products follow the EIA/TIA 568 standard. There are two wire color-

code standards: EIA/TIA 568A and EIA/TIA 568B. Either standard can be used
for making connections as long as the RJ-45 jacks at both ends of each
cable follow the same standard.

• Measure wire distance by:

1. Shorting the two conductors together at the far end, and measuring

the loop-resistance by an Ohmmeter.

2. Use

the

Loop Resistance table to calculate the distance.

• DO NOT connect coax cables longer than 100 ft. (30 M) to the BNC

connectors of any GE UTP equipment.

• All measured distances should include any coax cables in the path.

• Verify camera current requirements and wire resistance limits for the

maximum distance that power can travel. Use the Power Distance Chart to
verify the wire distance.

• GE VPD products require Unshielded Twisted-Pair (UTP) wires Category 2 or

better, 24 AWG (0,5 mm) or thicker.

This manual is related to the following products: