Control Room Installation

UTP:

• Connect the UTP wires carrying video signals to the terminal block input of

the receiver hub. If the UTP is terminated with a RJ-45 connector, then use
either the RJ-45 connector or provided RJ-45 adapter to connect to the
transceiver hub.

• Make sure that the same UTP pair and polarity are used on both transmit

and receive sides.

Video:

• Use provided 2-foot (60 cm) coax patch cords to connect the BNC video

inputs of video receiving devices such as DVRs or matrix switches.

Power:

GEC-4VARHUB-4

• Connect the ground screw connector to a qualified earth ground using a

short thick wire.

• Connect the external power supply cable to the power input connector of the

GEC-4VARHUB-4.

Note:

This product is intended to be supplied by a UL Listed Direct Plug-In Power

Unit marked “Class 2” or “LPS” and output rated 12 VDC, 1 Amp minimum.

All other models

• Connect the AC power cord to a grounded AC power outlet.

• The receiver hubs do not require any adjustments. They are equipped with

Automatic Video Compensation (AVC) circuit that automatically adjusts the
video quality regardless of video content.