may switch to next video from door station since the device support 8-ch videos at the same

time with 1 large window and 7 small windows.

You may turn it off by pressing monitor button again and VDP will return to standby

interface.

2.2.5 Call Record Function

Under

“video bidirectional talk” status click “call record”, you will see missed calls,

received calls, and dialed calls, which include information of caller and time. You may go to

different pages of records. You also may call, save, delete or delete all callers.

2.2.6 Contacts

Under “video bidirectional talk” status click “call resident”, you may enter contacts by

clicking contacts icon (on the right of call box). The interface includes information of saved

VDP info which allows direct operation to call, add, edit, delete and delete all. You may add by

clicking blank or add button to add resident info. You may edit resident info by selecting saved

info and click edit button.

2.3 Alarm Function

This product can be connected to up to 8 channels alarm with 1st channel as SOS button,

2nd channel as gas alarm, 3rd channel as smoke alarm while the remaining 5 channels can be

flexibly set.

Under sub-menu there is information of protection zone status, alarm records and mode

setup.

2.3.1 Protection Zone Status Function

This device mainly displays information of protection zone type, current status, and delay

time for the 8 protection zones. Users may enter setup interface of protection zone by clicking

setup button (password required), and can set contents such as protection zone type, NO/NC,

alarm type, enter delay, exit delay. For 1

st

to 3

rd

channels therein, users can only set NO/NC

type; for the remaining 5 channels, users can set all, while protection zone types consist of IR,

gas, smoke, SOS, door sensor, theft alarm, tripwire. Enter and exit time can be set to 0s, 10s,

30s, 60s, 90s and 120s. Delay is available only with delay alarm setup.

Users can make bypass and delete each protection zone, or make the selected protection

zone invalid once or for longer period.

2.3.2 Alarm Recording Function

Alarm recording mainly records information of the time alarm happens, protection zone

NO., alarm processed or not. The alarm info will be updated to management platform

synchronously.