background image


Dtr cts wiggle

CTS should be high well before DTR is dropped (1/18). DTR low times should be at least
one timer tick (1/18) long and no longer than two ticks. This wiggle does not work 100%
compared to older products. It is the same as sending “ESC % C 1 N 8 1 cr” and “ESC % A 0
cr.” Go to effect at *2. CTS should be low for at least one timer tick and DTR should be
high during this time. At time *3, the tablet will send “T” and for each time CTS is toggled,
one more “T” will be sent. To get out of this mode, send the table “ESC % VR cr” for a hard
reset or use the “ESC %A1” command.

Formats

20 Format AFT

Transducer Types