Ec2-9, Philips, Lightoliièr – Philips Lightolier EC2-9 User Manual
Page 3: Lighting systems
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

LIGHTOLIIÈR*
Lighting Systems
EC2-9
Page 3 of 3
Energos Control System 2-Light T8 per 4' (121.92cm) (Nominal) Lens
Ballast Ordering Information
Lamp Ordering Information
Design
Lamp Type
Ballast Factor
Start Type
THD %
D
T8
0.71
Program
<10
E
T8
0.88
Program
<10
H
DimT8
1.00/.05
Program
<10
Design
Lamp Type
Wattage
Rated Output
(Lumens)
Color(K)
A
T8
28
2725
3000
B
T8
28
2725
3500
C
T8
28
2725
4100
D
T8
30
2850
3000
E
T8
30
2850
3500
F
T8
30
2850
4100
G
T8
32
3000
3000
H
T8
32
3000
3500
1
T8
32
3000
4100
J
T8
32
3100
3000
K
T8
32
3100
3500
L
T8
32
3150
4100
Lamp and Ballast System Data
Design
Lamp Type
(T8 or T5)
Ballast
Factor (BF)
Ballast
THD (%)
Lamp Rated
Wattage
Lamp
Rated
Output
Lamp
Color
(Kelvin)
IES Output
(lumens)
System
Input
Watts
System
Efficacy
(lum/watt)
System
Lamp Life
(Hours)
Start
Type
DA
T8
0.71
<10
28
2725
3000
2199
20.0
96.74
24000
Program
DB
T8
0.71
<10
28
2725
3500
2199
20.0
96.74
24000
Program
DC
T8
0.71
<10
28
2725
4100
2199
20.0
96.74
24000
Program
DD
T8
0.71
<10
30
2850
3000
2299
21.5
94.12
24000
Program
DE
T8
0.71
<10
30
2850
3500
2299
21.5
94.12
24000
Program
DF
T8
0.71
<10
30
2850
4100
2299
21.5
94.12
24000
Program
DG
T8
0.71
<10
32
3000
3000
2420
23.0
92.61
24000
Program
DH
T8
0.71
<10
32
3000
3500
2420
23.0
92.61
24000
Program
DI
T8
0.71
<10
32
3000
4100
2420
23.0
92.61
24000
Program
DJ
T8
0.71
<10
32
3100
3000
2501
23.0
95.70
30000
Program
DK
T8
0.71
<10
32
3100
3500
2501
23.0
95.70
30000
Program
DL
T8
0.71
<10
32
3150
4100
2541
23.0
97.24
30000
Program
EA
T8
0.88
<10
28
2725
3000
2725
25.5
94.04
24000
Program
EB
T8
0.88
<10
28
2725
3500
2725
25.5
94.04
24000
Program
EC
T8
0.88
<10
28
2725
4100
2725
25.5
94.04
24000
Program
ED
T8
0.88
<10
30
2850
3000
2850
27.5
91.20
24000
Program
EE
T8
0.88
<10
30
2850
3500
2850
27.5
91.20
24000
Program
EE
T8
0.88
<10
30
2850
4100
2850
27.5
91.20
24000
Program
EG
T8
0.88
<10
32
3000
3000
3000
29.0
91.03
24000
Program
EH
T8
0.88
<10
32
3000
3500
3000
29.0
91.03
24000
Program
El
T8
0.88
<10
32
3000
4100
3000
29.0
91.03
24000
Program
EJ
T8
0.88
<10
32
3100
3000
3100
29.0
94.07
24000
Program
EK
T8
0.88
<10
32
3100
3500
3100
29.0
94.07
24000
Program
EL
T8
0.88
<10
32
3150
4100
3150
29.0
95.59
24000
Program
HG
T8 DIM
1.0/0.5
<10
32
2850
3000
2850/ 143
34/8
83.80
NA
Program
HH
T8 DIM
1.0/0.5
<10
32
2850
3500
2850 / 143
34/8
83.80
NA
Program
HI
T8 DIM
1.0/0.5
<10
32
2850
4100
2850 / 143
3 4 / 8
83.80
NA
Program
*25°C Rating
All data is per 1 lamp on a two lamp system at 277 VAC.
Data is based on Osram Sylvania specifications.
When ordering no lamps provided by Lightolier, use lamp code "Z"
Do not alter lumen values or ballast factor light losses when completing
calculations using Energos lES files. Eiles have already been adjusfed. The lumen
value for fhe lamp (wifhin a Lighfing Design program) will be fhe lES Oupuf value
shown on fhis fable.
The lamp life fable demonsfrafes fhe effecfs of shortened cycle-times with both
program start and instant start ballasts. The graph shows that instant ballasts
are susceptible to shortened lamp life if short cycle periods of less fhan 3 hours
are used. Eor cycle periods of greaferfhan 3 hours program sfart ballasf are not
required.
Lamp Life Table using program sfart and instant start ballasts.
Job Information
Type:
631 Airport Road, Eall River, MA 02720 • (508) 679-8131 • Lax (508) 674-4710
We reserve the right to change details of design, materials and finish.
Lightolier is a Philips group brand
PHILIPS