Technical data, Packaging content – Fredenstein U70F User Manual
Page 6
Fredenstein U70F Peak Programme Meter
Fredenstein U70F Manual V2.1 July 16, 2014 Page 5
Technical Data
:
Inputs and outputs
balanced XLR connectors with audio pass‐through
Insertion loss
0 dB
20 kHz ‐0.25 dB
Frequency response
20 Hz to
Peak Attack time
< 10ms
RMS Integration time
330ms
Sampling frequency
200 kHz
1.5s/20dB in 1dB/step, 2.25s/20dB in 0.5dB/step
Release time
Maximum input level
+28dBu
Input impedance
> 5 kΩ
+4 dBu (1.23V sine‐wave at 1kHz) for 0 dB
Standard calibration
level
reading
C, 50 – 60 Hz with IEC power‐cord
Mains
90 – 240VA
Power consumption
Max. 15W
Fuse
0.5AT (5x20 Type)
X50mmX140mm
Dimensions(LxHxD)
482mm
1.6Kg
Weight
Packaging content:
U70F PPM Meter
x 1
ountry specific power cord
x 1
perating Manual (English)
x 1
C
O