Fredenstein U70F Peak Programme Meter

 

Fredenstein  U70F  Manual  V2.1 July 16, 2014   Page 5 

Technical Data

Inputs and outputs

 

balanced XLR connectors with audio pass‐through

Insertion loss

 

0 dB

 

 20 kHz ‐0.25 dB

 

Frequency response

 

20 Hz to

 

Peak Attack time

 

< 10ms

RMS Integration time 

330ms 

Sampling frequency

 

200 kHz

 

1.5s/20dB in 1dB/step, 2.25s/20dB in 0.5dB/step

 

Release time

 

Maximum input level

 

+28dBu

 

Input impedance

 

> 5 kΩ

 

+4 dBu (1.23V sine‐wave at 1kHz) for 0 dB 

Standard calibration 

level

 

reading

 

C, 50 – 60 Hz with IEC power‐cord

 

Mains

 

90 – 240VA

Power consumption

 

Max. 15W

 

Fuse

 

0.5AT (5x20 Type)

 

X50mmX140mm 

Dimensions(LxHxD)

 

482mm

1.6Kg 

Weight 

 

 

Packaging content: 

 

 

U70F PPM Meter   

 

x 1 

ountry specific power cord

x 1 

perating Manual (English) 

x 1 