3.8. GPI Remote Control Ports

The rear panel of the MIMO88 offers 8 GPI inputs (16) for 0-10 VDC continuous control voltage. Each of

these inputs can be connected to an external physical device (potentiometer, contact closure, continuously variable
voltage 0-10V DC, etc.) and assigned to a MIMO88 function, as for example:

 Input, output channel or matrix crosspoint volume remote control by means of a WPVOL physical

knob or an Ecler WP Series WPVOL-IR remote control

 MUTE or SOLO activation/deactivation by means of a switch or contact closure
 Recalling

a

preset with a push button or contact closure

GPI connectors are screw terminal blocks with three-contacts. The wiring is as follows:

Positive, + 10 VDC

>

Pin +

Variable voltage, 0-10 VDC

>

Pin

Ground

>

Pin

Examples of connection

Connecting cables can be up to 500 meters with a minimum section of 0.5 mm

2

.

Consult your ECLER dealer or www.ecler.com about the WP series remote control wall panels and other

accessories available for connection to the REMOTE/VCA port.

3.9. GPO Remote Control Ports

The rear panel of the MIMO88 offers 8 NO/NC (normally open/ normally closed) relay outputs (17). Each of

these outputs may be assigned to a MIMO88 function, such as a button of EclerNet Manager (MUTE key, SOLO
key, etc.). This makes it possible to interact with external devices such as projection screen motors or movable
partitions, lights, sirens, other equipment GPI entries, etc.3.10. Remote control RS-232 Port

3.10. Remote control RS-232 Port

The built-in RS-232 port in the rear panel allows an external device to communicate with an MIMO88 unit

via a serial connection. Said connection uses the TP-NET protocol syntaxis so to enable the external device to
obtain the value of any of the parameters of the MIM088 unit (by "GET" commands) and/or modify said values
(“SET” commands). See the TP-NET protocol manual for more information.

The serial connection should comply with the following specifications:

Baud rate: 57600 (fixed, no autonegotiation)
Data bits: 8
Parity: None
Stop bits: 1

Flow

control:

None

WIRING RS232 – DB9

RS232 DB9

Tx

Pin 2 (RxD)

Rx

Pin 3 (TxD)

Gnd

Pin 5 (Signal Gnd)