Ecler MIMO 88 User Manual
Page 37
37
Miscellaneous
Management Connectivity:
Ethernet
Ethernet Base-Tx 10/100Mb Auto X-Over CAT5 up to 100m.
RS-232
Baud rate: 57600 (fixed, no autonegotiation)
Data bits: 8
Parity:
None
Stop
bits:
1
Flow
control:
None
Expansion LINK BUS (16x16 ch.)
Proprietary over CAT5, Xover cable up to 100m.
Remote Bus
2, over twisted pairs; up to 1km (see specific specs.)
GPI
8, from 0 to 10VDC or TTL level
GPO
8, 3 poles isolated relay; 1A, 48VDC max.
Aux. Power Supply for Remotes & GPI
+12VDC, 1.2A. max. (short circuit protected)
Time and date retention (battery)
1 month aprox. (ambient temperature dependant)
RTC
accuracy
±1
minute
/year
SOFTWARE
EclerNet Software
- Realtime full GUI of all functions and controls thru Ethernet with
interactive graphical display
- Grouping mode channels or devices
- Grouping of other groups
- Automated report generation
- Up to 256 devices on same net.
- Autodiscovery devices feature
- Routing capability through NAT gateways.
- Real time metering at input/output (DSP)
- Device “Finder” feature
- Save & Recall setup and preset functions
- Firmware update capability thru Ethernet
- Password protection (device & project with two user levels)
- Default Network configuration:
IP:
192.168.0.100
Mask:
255.255.255.0
Gate:
192.168.0.1
UDP Port: 2210
Operating System:
Windows® W2000 Prof. (SP4); XP Prof. (SP3); Vista (SP1), W7
Minimum EclerNet System Requirements: Pentium IV ® 1GHz
512MB
RAM
40MB HDD free space
800x600 pixels & 16bits color display
10/100/1G Ethernet Network card