6. USE

1. Location and installation:

The following general rules should be observed:

Stand or hang the cabinets on or from solid, firm surfaces.

There must be no obstacles between the acoustic box and the audience. High
frequencies, unlike low ones, are extremely directive and any obstacle will cause an
attenuation in its response.

For large audience areas, the higher the boxes are placed, the better the propagation of
the sound over the distance. To achieve this, use standardised tripods (with a stem 35 mm
in diameter, such as the ECLER TRIPO1 model), which should be inserted into the casing
specially provided for that purpose which is located on the inner side of the box.

The VERSO 8P, 10P and 12P are also prepared for operation on the ground when laid flat
(e.g., for use as a stage monitor), without the need to use any optional accessories.

For wall mounting, an optional accessory is required: reference SR12 for the VERSO 12P
model / reference SR8 for the VERSO 10P and 8P models. In this case, an additional
safety cable should also be used (see details in section 9).

If the boxes are hung, 6 anchoring points will be required: 3 nuts embedded on the top
side and 3 more on the lower side, located under the rubber feet (see diagram in section
9).

Do not hang the equipment by its carry handles.


2. Connecting to the mains:

The VERSO 8P, 10P and 12P models operate at a voltage of 115/230 V AC (selector

switch on rear panel) and at 50-60Hz. Always ensure the mains selector switch is correctly
positioned before starting up the unit: otherwise serious damage might be caused.

Ensure that the mains cable is not mixed with the audio signal cables, thereby preventing

interferences and buzzing.

To protect the system from potential electrical overloads there is a T5A 250V 5x20 type

mains fuse for model 12P, T3.5A 250V 5x20 for model 10P and T2.5A 250V 5x20 for model 8P. In
the event of fusing, disconnect the appliance and replace it by another with identical characteristics.
If the new fuse blows immediately, consult our Technical Service.

ATTENTION: DO NOT SHORT-CIRCUIT THE PROTECTION CIRCUIT OR INSTALL A
FUSE WITH A VALUE HIGHER THAN THE ORIGINAL ONE.
WARNING: The fuse must be replaced by a qualified technician.


3. Audio input connections:

These are of the balanced type and XLR3-type connectors, as indicated:

Phase or direct signal (+)

>

Pin 2

Non-Phase or inverted signal (-)

>

Pin 3

Ground

>

Pin 1

Depending on the position in which the LINE /MICRO switch is set, the input will admit

signals from one level or the other: