Ecler NPA SERIES User Manual
Page 48
48
DIGITAL
Processing:
A/D & D/A
24 bit, 96kHz. S/N:110dB/115dB AKM
DSP 32/64
bits
Latency
824
μs
Analog Input headroom:
+18 dBV = +21dBu
Digital Input attenuator:
Stepless from –
∞ to +0dB
Input Impedance:
Balanced, 22k
Ω
Maximum Delay:
1s (343.4m) total for all 2 channels.
Delay resolution:
10.4µs (3mm)
Compressor / Limiter:
Threshold
from -36dBV to +18dBV
Ratio
1:1 to
∞:1 (limiter)
Attack time
Auto or from 0.1ms to 500ms.
Release time
Auto or from 1ms to 5s.
High & Low pass Crossover filters
Butterworth in 6/12/18/24dB/oct.
Bessel in 12/18/24dB/oct
Linkwitz-Riley in 12/24dB/oct.
Parametric Eq types (8 max. per output)
- Bypass / On-Off all channels
- Param. Eq. 20Hz-20kHz; -60/+12dB; Q from =.3 to 200
- Low & High Shelf 6/12 dB/oct
- Low & High Pass 6/12 dB/oct.
- All-Pass 1/2 order
Built In signal generator
- Sine (20Hz to 20kHz)
- Polarity(20Hz to 20kHz)
-
White
-
Pink
Signal Mute
Yes
Signal Polarity Invert
Yes
Connectivity:
- Ethernet Base-Tx 10/100Mb Auto X-Over Cat5
-
Rs-232
- Fault relay N.O./N.C.
- AES / EBU (In / Out) 8kHz to 96kHz (may be optional
on some units).