beautypg.com

Owner’s manual, Technical service, Specifications service hints – Desa Tech CGN20TA User Manual

Page 17: Service publications, Cleaning and maintenance, Replacement parts

background image

17

104190

OWNER’S MANUAL

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting.

If so, contact DESA International’s
Technical Service Department at
1-800-323-5190.

CGN20TA

Btu (Variable)

10,000/20,000

Type Gas

Natural Only

Ignition

Piezo

Pressure Regulator Setting

3" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

Minimum

4"

Dimensions, Inches (H x W x D)

Heater

23.5 x 18.5 x 8.0

Carton

25.8 x 21.3 x 10.1

Weight (pounds)

Heater

22

Shipping

27

SPECIFICATIONS

SERVICE HINTS

When gas pressure is too low

• pilot will not stay lit

• burner will have delayed ignition

• heater will not produce specified heat

When gas quality is bad

• pilot will not stay lit

• burner will produce flames and soot

• heater will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
natural gas supplier.

SERVICE
PUBLICATIONS

You can purchase a service manual from the
address listed on the back page of this
manual. Send a check for $5.00 payable to
DESA International.

CLEANING
AND
MAINTENANCE

ODS/PILOT AND BURNER

• Use a vacuum cleaner, pressurized air,

or small, soft bristled brush to clean.

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air

to clean.

Exterior

• Use a soft cloth dampened with a mild

soap and water mixture. Wipe the cabi-
net to remove dust.

WARNING: Turn off heater

and let cool before cleaning.

CAUTION: You must keep

control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a
qualified service person. Heater
may need more frequent clean-
ing due to excessive lint from
carpeting, bedding material, etc.

REPLACEMENT
PARTS

Note:

Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

Parts Under Warranty

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), either contact your nearest Parts
Central (see below) or call DESA
International’s Technical Service Depart-
ment at 1-800-323-5190 for referral infor-
mation.

When calling DESA International, have
ready

• your name
• your address
• model number of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural

gas)

• purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), either contact your nearest Parts
Central (see below) or call DESA
International’s Parts Department at 1-800-
972-7879 for referral information.

When calling DESA International, have
ready

• model number of your heater
• the replacement part number