beautypg.com

Blue flame vent-free natural gas heater cgn20ta, Troubleshooting – Desa Tech CGN20TA User Manual

Page 14

background image

14

104190

Blue Flame Vent-Free Natural Gas Heater

CGN20TA

TROUBLESHOOTING

Note:

All troubleshooting items are listed in

order of operation.

WARNING: Turn off and un-

plug heater and let cool before
servicing. Only a qualified ser-
vice person should service and
repair heater.

CAUTION: Never use a wire,

needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.

POSSIBLE CAUSE

1. Ignitor electrode positioned wrong
2. Ignitor electrode broken
3. Ignitor electrode not connected to igni-

tor cable

4. Ignitor cable pinched or wet

5. Piezo ignitor nut is loose

6. Broken ignitor cable
7. Bad piezo ignitor

1. Gas supply turned off or manual shutoff

valve closed

2. Control knob not in PILOT position
3. Control knob not pressed in while in PI-

LOT position

4. Air in gas lines when installed

5. ODS/pilot is clogged

6. Gas regulator setting is not correct

1. Control knob not fully pressed in
2. Control knob not pressed in long enough

3. Safety interlock system has been trig-

gered (Thermostat models only)

4. Manual shutoff valve not fully open
5. Thermocouple connection loose at con-

trol valve

6. Pilot flame not touching thermocouple,

which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A)

Low gas pressure

B)

Dirty or partially clogged ODS/

pilot

7. Thermocouple damaged
8. Control valve damaged

REMEDY

1. Replace ignitor
2. Replace ignitor
3. Reconnect ignitor cable

4. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry

5. Tighten nut holding piezo ignitor to

heater cabinet. Nut is located inside
heater cabinet at top

6. Replace ignitor cable
7. Replace piezo ignitor

1. Turn on gas supply or open manual

shutoff valve

2. Turn control knob to PILOT position
3. Press in control knob while in PILOT

position

4. Continue holding down control knob.

Repeat igniting operation until air is re-
moved

5. Clean ODS/pilot (see Cleaning and

Maintenance, page17) or replace ODS/
pilot assembly

6. Replace gas regulator

1. Press in control knob fully
2. After ODS/pilot lights, keep control

knob pressed in 30 seconds

3. Wait one (1) minute for safety interlock

system to reset. Repeat ignition operation

4. Fully open manual shut-off valve
5. Hand tighten until snug, then tighten 1/4

turn more

6. A) Contact local natural gas company

B) Clean ODS/pilot (see Cleaning and
Maintenance
, page 17) or replace ODS/
pilot assembly

7. Replace thermocouple
8. Replace control valve

OBSERVED PROBLEM

When ignitor button is pressed, there is no
spark at ODS/pilot

When ignitor button is pressed, there is
spark at ODS/pilot but no ignition

ODS/pilot lights but flame goes out when