beautypg.com

Owner’s manual, Checking gas connections – Desa Tech CGN20TA User Manual

Page 11

background image

11

104190

OWNER’S MANUAL

WARNING: Test all gas pip-

ing and connections for leaks
after installation or servicing.
Correct all leaks at once.

WARNING: Never use an open

flame to check for a leak. Apply a
mixture of liquid soap and water
to all joints. Bubbles forming
show a leak. Correct all leaks at
once.

PRESSURE TESTING GAS
SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2
PSIG

1.

Disconnect heater and its individual
manual shutoff valve from gas supply
piping system. Pressures in excess of
1/2 psig will damage heater regulator.

2.

Cap off open end of gas pipe where
manual shutoff valve was connected.

3.

Pressurize supply piping system by ei-
ther using compressed air or

opening main gas valve located on or
near gas meter.

4.

Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

CHECKING GAS
CONNECTIONS

Test Pressures Equal To or
Less Than 1/2 PSIG

1.

Close manual shutoff valve (see Fig-
ure 14).

2.

Pressurize supply piping system by ei-
ther using compressed air or opening
main gas valve located on or near gas
meter.

3.

Check all joints from gas meter to
manual shutoff valve (see Figure 15).
Apply mixture of liquid soap and wa-
ter to gas joints. Bubbles forming show
a leak.

4.

Correct all leaks at once.

PRESSURE TESTING
HEATER GAS
CONNECTIONS

1.

Open manual shutoff valve (see Fig-
ure 14).

2.

Open main gas valve located on or near
gas meter.

3.

Make sure control knob of heater is in
the OFF position.

4.

Check all joints from manual shutoff
valve to thermostat gas valve (see Fig-
ure 15). Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

6.

Light heater (see Operating Heater,
pages 12 and 13). Check the rest of the
internal joints for leaks.

7.

Turn off heater (see To Turn Off Gas to
Appliance
, page 12).

8.

Replace front panel.

ON

POSITION

OFF

POSITION

Figure 14 - Manual Shutoff Valve

Manual
Shutoff
Valve

Open

Closed

Thermostat Gas Valve

Gas Meter

Figure 15 - Checking Gas Joints

Manual
Shutoff
Valve