3.2 Nominal data
Motor
M4D138-HF
Phase
3~
3~
Nominal voltage / VAC
230
400
Connection
Δ
Y
Frequency / Hz
50
50
Type of data definition
ml
ml
Valid for approval /
standard
CE
CE
Speed / min
-1
1310
1310
Power input / W
2180
2180
Current draw / A
6.75
3.9
Min. back pressure / Pa
0
0
Min. ambient temperature
/ °C
-40
-40
Max. ambient
temperature
/ °C
55
55
Starting current / A
24
14
Maximum safe operating
speed / min
-1
2425
@ 55 °C
2425
@ 55 °C
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
A
Efficiency category
Static
Variable speed drive
No
Specific ratio
*
1.01
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
/ %
37.5
30.3
37.3
Efficiency grade N
44.2
37
44
Power input P
e
/ kW
0.87
Air flow q
v
/ m³/h
2005
Pressure increase total p
sf
/ Pa
593
Speed n / min
-1
1435
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass
19.7 kg
Size
310 mm
Surface of rotor
Cast in aluminium
Material of impeller
Sheet steel, galvanised
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 54
Insulation class
"F"
Humidity class
F3-1
Mounting position
Any
Condensate discharge
holes
On rotor and stator sides
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Motor protection
Thermal overload protector (TOP)
brought out
Cable exit
Lateral
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 61800-5-1; EN 60034-1 (2010); CE
Approval
EAC; VDE
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 10032-5-9970 · ENG · Revision 84865 · Release 2015-01-27 · Page 5 / 10