3.2 Nominal data

Motor

M4D094-FA

Phase

3~

3~

Nominal voltage / VAC

400

400

Connection

Y

Y

Frequency / Hz

50

60

Type of data definition

fa

ml

Valid for approval /
standard

CE

CE

Speed / min

-1

1350

1500

Power input / W

380

540

Current draw / A

0.75

0.94

Min. back pressure / Pa

0

50

Min. ambient temperature
/ °C

-40

-40

Max. ambient
temperature
/ °C

90

55

Starting current / A

2.8

2.7

Maximum safe operating
speed / min

-1

3020

3020

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

/ %

34.2

26

33

Efficiency grade N

45.2

37

44

Power input P

e

/ kW

0.18

Air flow q

v

/ m³/h

755

Pressure increase total p

sf

/ Pa

295

Speed n / min

-1

1445

Data definition with optimum efficiency.

The ErP data is determined using a motor-impeller combination in a standardised

measurement configuration.

3.4 Technical features

Mass

9.5 kg

Size

225 mm

Surface of rotor

Coated in black

Material of impeller

Sheet steel, galvanised

Housing material

Sheet steel, galvanised

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 54

Insulation class

"F"

Humidity class

F4-1

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

<= 3.5 mA

Motor protection

Thermal overload protector (TOP)
brought out

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60034-1 (2010); CE

Approval

CCC; EAC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 11992-5-9970 · Revision 82513 · Release 2014-05-08 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com